Dymax MD® 215-CTH-SV01-UR-SC
Dymax MD® 215-CTH-SV01-UR-SC is an LED-curable adhesive designed for next-gen catheter assembly, bonding challenging materials like Nylon 12 and PEBA. It incorporates See-Cure and Ultra-Red® fluorescence for visual cure confirmation and inspection.
Dymax MD® 215-CTH-SV01-UR-SC Features:
- UV/Visible and LED curable (385 nm)
- See-Cure technology (blue to clear cure indicator)
- Ultra-Red® fluorescence for inspection
- Designed for bonding hard-to-bond plastics
Dymax MD® 215-CTH-SV01-UR-SC Applications:
- Catheter assembly (balloon/lumen, hub/lumen)
- Marker band bonding
- Manifold joints
About Prostech
Prostech Philippines is a one-stop solution provider for specialty materials and equipment across electronics manufacturing, from PCBA to final assembly. Our core material and equipment solutions include:
- PCB Assembly Materials
- Cleaning & Degreaser
- Circuit Board Protection
- Thermal Management Solutions
- EMI Shielding
- General Assembly Adhesives
- Elastomeric Materials
- Process Equipment: Potting & Coating Systems, UV/ Heat Curing, Plasma Treatment, Tape placement automation, and cleaning machines
Technical Added Value to customer
Prostech offers customized material and process equipment solutions with engineering support throughout R&D, production process optimization, and performance validation. Our in-house lab located in Alabang, Muntinlupa is equipped to conduct electronics material testing, application simulation, and adhesive validation, helping customers reduce the need for onsite trials and accelerate implementation.
International Supply Chain Advantage
Regional warehouse hubs across Vietnam, Singapore, Malaysia, and the Philippines ensure cross-border reliable supply. In Philippines PEZA-bonded warehouse located at Lima Industrial Park, Batangas enables Prostech to provide responsive, demand-based delivery and significantly shortens standard lead time for Philippines customers.
Need help selecting the right product or solution?
UNCURED PROPERTIES * | ||
Property | Value | Test Method |
Solvent Content | No Nonreactive Solvents | N/A |
Chemical Class | Acrylated Urethane | N/A |
Appearance | Blue Translucent Liquid | N/A |
Soluble in | Organic Solvents | N/A |
Density, g/ml | 1.01 | ASTM D1875 |
Viscosity, cP (20 rpm) | 1,100 (nominal) | DSTM 520 |
Shelf Life @RT (22°C to 25°C) from Date of Manufacture | 7 months | N/A |
UNCURED PROPERTIES * | ||
Property | Value | Test Method |
Solvent Content | No Nonreactive Solvents | N/A |
Chemical Class | Acrylated Urethane | N/A |
Appearance | Blue Translucent Liquid | N/A |
Soluble in | Organic Solvents | N/A |
Density, g/ml | 1.01 | ASTM D1875 |
Viscosity, cP (20 rpm) | 1,100 (nominal) | DSTM 520 |
Shelf Life @RT (22°C to 25°C) from Date of Manufacture | 7 months | N/A |
OTHER CURED PROPERTIES * | ||
Property | Value | Test Method |
Refractive Index (20°C) | 1.50 | ASTM D542 |
Boiling Water Absorption, % (2 h) | 5.1 | ASTM D570 |
Water Absorption, % (25°C, 24 h) | 9.6 | ASTM D570 |
Linear Shrinkage, % | 2.1 | ASTM D2566 |
Glass Transition Tg, °C | 76 | ASTM D5418 |
CTEa1, mm/m/˚C | 147 | ASTM E831 |
CTEa2, mm/m/˚C | 289 | ASTM E831 |
CURING EQUIPMENT RECOMMENDATIONS * | |||
Process Method | Spot Lamp | Flood Lamp | Conveyor |
| BlueWave® MX- | BlueWave® AX- | UVCS Conveyor |
LED | 150 | 550 | with BlueWave® AX- |
Curing/Wavelength | PrimeCure® 385 | PrimeCure® 385 | 550 PrimeCure® 385 |
| nm | nm | nm |
Broad Spectrum | BlueWave® | 5000-ECE | UVCS Conveyor with Fusion F300S |