RTV102, RTV103, RTV106, RTV108, RTV109, RTV112, RTV116 and RTV118 one-component, ready-to-use adhesive sealants are extremely versatile. They cure to a tough, durable, resilient silicone rubber on exposure to atmospheric moisture at room temperature. Acetic acid vapors are released from the sealant surface as a by-product of cure.
RTV102, RTV103, RTV108 and RTV109 sealants are standard strength paste consistency products which can be applied to vertical and overhead surfaces where pourable/self-leveling sealants are not practical. RTV112 and RTV118 sealants are self-leveling products which are preferable to pasteconsistency sealants when flow into small crevices and hard-to reach places is desired. RTV106 sealant is paste-consistency sealant. RTV116 sealant is a self-leveling sealant.
Both RTV106 and RTV116 sealants are standard strength high temperature sealants. Since all these sealants utilize a moisture cure system, they must not be used in thicknesses of greater than 6mm (1/4 in.). Where section depths exceed 6mm (1/4 in.), Momentive Performance Materials one component, addition cure or two-component silicone rubber compounds are recommended.
Key Features
- One-component products
- Capability to cure at room temperature and ambient humidity
- Self adhesion properties
- Low temperature flexibility
- High temperature performance
- Excellent weatherability and ozone and chemical resistance
- Excellent electrical insulation properties
Applications
- General purpose bonding, sealing, electrical insulation, formedin-place gaskets. Can be applied to vertical or overhead surfaces
- Sealing heating elements, gasketing, electrical insulation, and other critical bonding and sealing applications where parts must perform at high temperatures. Can be applied to vertical or overhead surfaces.
- Thin section potting, filling small surface voids, self leveling protective coating, electrical insulation where high temperature performance is required.
- Electrical insulation, thin section potting, self leveling protective coatings. Will flow into small crevices and hard to reach places.
- These sealants were not designed for and should not be used for applications intended for permanent implantation into the human body.
- These sealants are not for use in delicate electrical and electronic applications in which corrosion of copper, brass or other sensitive metals is undesirable.
Uncured Properties |
RTV102 RTV103 RTV108 RTV109 |
RTV106 |
RTV116 |
RTV112 RTV118 |
Consistency |
Paste |
Paste |
Self leveling |
Self leveling |
Color |
RTV102: White RTV103: Black RTV108: Translucent RTV109: Aluminum |
Red |
Red |
RTV112: White RTV118: Translucent |
Viscosity, poises |
– |
– |
250 |
200 |
Application Rate, (g/min) |
400 |
400 |
– |
– |
Specific Gravity |
1.05 |
1.07 |
1.09 |
1.05 |
Tack-Free Time, minutes |
20 |
20 |
30 |
20 |
Cured Properties(1) |
RTV102 RTV103 RTV108 RTV109 |
RTV106 |
RTV116 |
RTV112 RTV118 |
Mechanical: |
|
|||
Tensile Strength, kg/cm2 (lb/in2) |
28 (400) |
26 (375) |
25 (350) |
23 (325) |
Elongation, % |
450 |
400 |
350 |
325 |
Hardness, Shore A |
30 |
30 |
20 |
25 |
Tear Strength, kg/cm (lb/in) |
8 (45) |
7 (40) |
– |
– |
Shear Strength, kg/cm2 (lb/in2)(2) |
14 (200) |
14 (200) |
7 (125) |
7 (100) |
Peel Strength, kg/cm (lb/in)(3) |
7 (40) |
7 (40) |
3 (25) |
3 (15) |
Electrical: |
|
|
||
Dielectric Strength, kv/mm (v/mil) |
20 (500) |
20 (500) |
16 (400) |
16 (400) |
Dielectric Constant @ 60 Hz |
2.8 |
2.8 |
2.8 |
2.8 |
Dissipation Factor @ 60 Hz |
0.001 |
0.001 |
0.001 |
0.001 |
Volume Resistivity, ohm-cm |
3×1015 |
3×1014 |
2×1014 |
6×1014 |
Thermal:(4) |
|
|
||
Brittle Point, °C (°F) |
-60 (-75) |
-60 (-75) |
-60 (-75) |
-60 (-75) |
Maximum continuous operating temperature, °C (°F) |
204 (400) |
260 (500) |
260 (500) |
204 (400) |
Maximum intermittent operating temperature, °C (°F) |
260 (500) |
315 (600) |
315 (600) |
260 (500) |
Additional Information:(4) |
|
|
||
Linear Shrinkage, % |
1.0 |
1.0 |
1.0 |
1.0 |
Thermal Conductivity, cal/sec/cm2, °C/cm |
0.0005 |
0.0005 |
0.0005 |
0.0005 |
(Btu/hr/ft2, °F/ft) |
(0.12) |
(0.12) |
(0.12) |
(0.12) |
Coefficient of Expansion cm/cm, °C |
27×10-5 |
27×10-5 |
27×10-5 |
27×10-5 |
(in/in, °F) |
(15×10-5) |
(15x-5) |
(15x-5) |
(15x-5) |
(1) Cure time 3 days at 25°C (77°F) / 50% relative humidity.
(2) At 100% cohesive failure.
(3) At 100% cohesive failure using 1 in. x 8 in. stainless steel screen at 180° pull angle.
(4) Information is provided for customer convenience only. These properties are not tested on a routine basis.